Typified Steel Connections
STY+
The program STY+ is used to design bolted moment-resisting beam connections of the type series IH as well as pinned I-beam connections of the type series IS, optionally with IK beam notches, following the guidelines of the German Steel Construction Association DSTV “Typisierte Anschlüsse im Stahlhochbau” (Typified Connections in Steel Construction), edition 2013.
Discover now more programs from the section Steel!
SHOW MOREMaterial
- Structural steel: S235 and S355
Structural systems
IH-connection:
- Moment-resisting connection with butt plate either flush to the surface or projecting on top or bottom and two or four vertical rows of bolts
- Beam-to-beam connection
- Connection of the beam to a continuous column with dimensioning of the column cross-section
- Connection of the beam to the top face of a column with dimensioning of the column cross-section
- Bolt strength classes 8.8 and 10.9
IS-connection:
- Pinned connection to a metal plate (as a connection to any kind of component)
- Pinned connection to a column web
- Pinned connection to beam web without a notch (i.e. connected in the centre of the web).
- Pinned connection to a beam web with a notch (on one or both sides)
- Pinned connection to a metal plate with a notch (on one or both sides)
- Bolt strength classes 4.6 and 10.9
Cross-sections:
- I-sections as standard shapes
Loads
IH-connection:
- Design internal forces from axial force, moment and shear force as well as from reverse moment, if applicable
- Multiple combinations of design internal forces can be entered
- Small negligible axial force Nd with verification of its application limit N/Npl < 0,05
IS-connection:
- Design values of the shear force Vz
- Multiple combinations of design internal forces can be entered
Design
The design process in the program is based on the implemented catalogue of the German Steel Construction Association DSTV which corresponds to the guideline “Typisierte Anschlüsse im Stahlhochbau” (Typified connections in steel construction), edition 2013.
The calculation of the connections is based on the component method, which decomposes the connection into each of its basic components. For each of the basic components, such as the column web in tension or the bolts in tension, the design resistance is determined. The global resistance is the sum of the resistances of the individual components.
All connections permissible for the defined system are listed as specified in the catalogue of the German Steel Construction Association DSTV. You can further refine the list by defining additional criteria such as the type of connection, the material or the screw strength or size. The program calculates the associated utilization for each specified type of connection and generates a well-structured presentation of the connection details including a 3-d model and a 2-d drawing.
Document file formats
- Word
- Printer
Output
- brief
- standard
- comprehensive output
- user-defined scope
Import options
- FRILO XML
Export options
- Word
- Nexus
- FRILO XML
- DXF-file
Steel construction
- DIN EN 1993
- DSTV-Ringbuch Ausgabe 2013
News
ALLPLAN is releasing powerful updates for structural analysis and design with FRILO 2025
Highlights include a direct interface to ALLPLAN for more efficient reinforcement of concrete columns, the new PLUS program SLS+ for the design of splice connections, and the option of designing transverse joints to timber beams with the HO12+.
Merger of FRILO Software and DC Software with ALLPLAN successfully completed
The merger of FRILO Software GmbH and DC-Software Doster & Christmann GmbH with the ALLPLAN Group has been legally completed since July 1, 2024.